Elstein HTS

 

 

Heat-up constant approx. 1,8 to    3,2 min

 

Permanent operating    temperature    up to 900 °C

Power densities up to 64 kW/m²

Energy saving by means of     integrated heat insulation

Radiator sizes and wattages     can    be combined

Radiators are optional available     with integrated thermocouple

HTS,HTS/1   

HTS/2   

HTS/4   

   

250

400

600

800

1000

W

125

200

300

400

500

W

60

100

150

200

250

W

Max.. Power per m2 radiation area

16

25.6

38.4

51.2

64

KW

Typical operating temperature *1

450

570

700

810

900

Max. permissibe temperature

700

750

800

850

900

Wavelength range

2-10

m

Heat-up time to 63% of final temperature

3.2

2.8

2.2

2

1.8

min

Cool-down time to 37% of final temperature

5.5

7.5

9.5

10

11

min

Typical temperature of exposedgoods(guideline)

180

230

270

300

330

*1: measured by using thermocouple@@*To Combination Cases@